Fire Protection & Safety Engineering

Our services in the division Fire Protection & Safety Engineering cover all measures for structural fire protection in accordance with the respective regulations. We enjoy supporting our customers already at planning stage. Doing so we provide experienced employees and a reliable network of experts. The execution of the fire protection and safety engineering measures is carried out by our well trained and experienced installation staff. We are independent from individual suppliers and guarantee a competent execution in all phases of the project.

In the following individual measures taken out from our service and product portfolio are given:
  • Seals for cables and pipes in fire-proof walls and ceilings
  • Fire protection coatings for cables
  • Fire protection claddings and linings for structural components
  • Fire-resistant walls
  • Fire-resistant and smoke-proof doors

For the installation on site we have fully equipped workshop vehicles, which allow a very flexible and quick reaction of our installation staff. For regular maintenance activities we are used to work with long term agreements, which are adjusted in accordance to our clients’ needs.

Examples for application and schematic drawings:

S90-sealing for cables and pipes made out of mineral fiber plates and fire protection coating Hilti CP673 in acc. with Z-19.15-1597


Source: Hilti

S90-sealing for cables and pipes made out of fire protection mortar Hilti CP 636 in acc. with Z-19.15-1148


Source: Hilti

Concealed fire break with mortar type Hilti CP 632 (MG III)


Source: Hilti

S90-sealing for cables and pipes type PROMASTOP®-Kombischott 90 Typ E, in acc. to Z-19.15-1452, made out of mineral fiber plates and fire-protection coating PROMASTOP®


Source: Promat,construction 600.46

S90-sealing for cables and pipes type PROMASTOP®-Mörtelschott 90 Kombi Typ S, in acc. to Zulassung Z-19.15-1725


Source: Promat,construction 620.15

R90-sealing type PROMASTOP®-UniCollar®, for pipes with diameters between 32 bis 200 mm


Source: Promat,construction 500.30

Sealing PROMASTOP®-NBR for insulated steel-, cast- or copper pipes. In case insulated inflammable pipes are installed through walls or roofs, the insulation material can be destroyed in case of fire. Consecutively the opening in the wall allows fire and smoke to penetrate in a new section of the plant. The insulation of the pipe can be covered with PROMASEAL®-coating closes in case of fire any openings and avoids further spreading of the fire.


Source: Promat,construction 500.40

Sealing PROMAGLAF®1200 for inflammable pipes in acc. to LAR may be used for all inflammable materials apart from aluminium and glass up to 160 mm outer diameter. The pipes are guided through the walls with an annular gap of maximum 50 mm.


Source: Promat,construction 500.45

Fire protection cladding for structural components made out of steel, the necessary wall thickness of the cladding is detemined by the classification of the fire resistance and the ratio U/A.


Source: Promat,construction 415

Fire protection lining for structural components made out of steel pipes, PROMATECT®-FS-pipe shells; Fire resistance between F30 to F120 can be achieved by maintaining the round profile.


Source: Promat,construction 445.86

F90 fire resistant wall


Source: Promat,construction 150.41

F90 fire resistant wall


Source: Promat,construction 450.41

Cable ducts for exposure to fire from inside or outside


Source: Promat,construction 290.20

Cable ducts for exposure to fire from inside or outside


Source: Promat,construction 290.25

Fire-resistant doors classified T 30, T 60 und T 90 in acc. to EN 1634-1, approved in acc. to DIN 4102; alternatively as smoke-proof doors in acc. to DIN 18095


Source: Teckentrup

Fire-resistant door with door locking system